Read more

August 21, 2019
3 min read
Save

Out-of-range alignment linked with tibial component migration after TKA

You've successfully added to your alerts. You will receive an email when new content is published.

Click Here to Manage Email Alerts

We were unable to process your request. Please try again later. If you continue to have this issue please contact customerservice@slackinc.com.

According to recently published results, mechanically out-of-range alignment was linked with higher tibial component migration after total knee arthroplasty.

Researchers measured coronal alignment parameters in full-leg radiographs from 85 cemented TKAs. Median follow-up was 11 years. Of the 85 TKAs, three underwent revision for aseptic loosening and four were considered loose. Investigators assessed the postoperative hip-knee angle relative to both the mechanical axis and constitutional alignment on tibial component migration. Linear mixed-effects model adjusted for sex, age, preoperative alignment, diagnosis and BMI was used for analysis.

In mechanically in-range knees, investigators did not see loose tibial components. However, they found all loose tibial components were out of range. After 5 years, the greatest mean migration in mechanically varus knees was 1.55 mm, was 1.07 mm for valgus knees and was 0.77 mm for in-range knees. Loose tibial components were seen in constitutionally in-range knees and in out-of-range knees. Comparable migration was seen among constitutionally in-range knees; however, more was seen in varus and in valgus knees, according to results from mixed model analyses. – by Monica Jaramillo

 

Disclosures: The authors report no relevant financial disclosures.