February 09, 2016
1 min read
Save

Nanophthalmic eyes show some significant improvements with high-powered IOL

You've successfully added to your alerts. You will receive an email when new content is published.

Click Here to Manage Email Alerts

We were unable to process your request. Please try again later. If you continue to have this issue please contact customerservice@slackinc.com.

Implantation of a foldable high-powered IOL significantly improved uncorrected distance visual acuity and spherical equivalent in nanophthalmic eyes, according to a study.

The retrospective case series consisted of 21 eyes of 13 patients with nanophthalmos who underwent cataract extraction and posterior chamber IOL implantation.

Patients received a CT Xtreme D IOL (Carl Zeiss Meditec), a customizable single-piece foldable monofocal aspheric IOL with refractive power ranging from +45 D to +60 D. The lens is injected through a 2.2-mm incision.

The primary outcome measure was change in spherical equivalence, and secondary outcomes were changes in logMAR uncorrected and corrected distance visual acuity. Mean follow-up was 9.6 months.

Spherical equivalence improved significantly, from a mean of +16.11 D preoperatively to +2 D postoperatively (P < .0001).

Uncorrected distance visual acuity improved significantly, from a mean of 1.47 logMAR before surgery to 0.74 logMAR after surgery (P = .016). The improvement in corrected distance visual acuity was not significant. IOP did not change significantly.

Serious postoperative complications were reported in five eyes (23.8%). Two eyes had malignant glaucoma, two eyes had vitreous hemorrhage, and one eye had vitreous hemorrhage with retinal detachment, leading to no light perception. – by Matt Hasson

Disclosure: Ahmed reports he is a consultant for Carl Zeiss Meditec. The remaining authors report no relevant financial disclosures.