Ratio of keratometric change to refractive change differs in change of spherical equivalent
Click Here to Manage Email Alerts
As refractive change increases, the change in simulated keratometry required to achieve 1.00 D of myopic refractive correction decreases, according to a study.
The retrospective review included 3,337 eyes that underwent LASIK or PRK. The ratio of keratometric change to refractive change was measured postoperatively at 3 months.
This data was compared between eyes with low (0.00 D to 2.99 D), moderate (3.00 D to 5.99 D) and high (6.00 D to 8.99 D) absolute change in spherical equivalent.
In the ratio of keratometric change to refractive change, significant differences were identified in all eyes when compared to absolute change in spherical equivalent (P < .001).
Regardless of preoperative keratometry, a significant difference in the ratio of keratometric change to refractive change also existed in all eyes (P < .028).