One-piece IOL yields good visual results for large and small pupils
Br J Ophthalmol. 2011;95(1):42-45.
Click Here to Manage Email Alerts
A one-piece acrylic IOL resulted in good visual acuity, contrast sensitivity, refraction and defocus curve in eyes with both large and small pupils, a study said.
The study included 51 eyes implanted with a Tecnis one-piece IOL (Abbott Medical Optics) after cataract surgery. The mean follow-up time was 3 months.
Mean total spherical aberration was reduced to almost zero in pupils with 3-, 4-, 5- and 6-mm optical zones.
Mean uncorrected visual acuity was 20/25 ± 8 letters, and mean best corrected visual acuity was 20/18 ± 4 letters. BCVA was the same using both a 3-mm and a 5-mm pinhole.
In addition, contrast sensitivity and defocus curves with both a 3-mm and a 5-mm pinhole did not show a statistically significant difference, the study said.